N Board Forum - Expanded Thread Page

Subject: Voltage regulator

[Back] [Return to Top of Forum]

Daniel Jinkens    Posted 11-20-2018 at 15:28:37 [URL] [DELETE]        [Reply] [Email]  
  • Voltage regulator
  • I'm asking if you have to reflash a voltage regulator every time if you have a master battery kill switch installed, and switch it on? Thanks for any advise in this matter.

    Bruce(OR)    Posted 11-20-2018 at 22:57:43 [URL] [DELETE]        [Reply] [No Email]  
  • Re: Voltage regulator
  • I master switched the neg side. My thinking was less arc when closing the switch and less power surge.

    Bob in KS    Posted 11-21-2018 at 10:45:29 [URL] [DELETE]        [Reply] [Email]  
  • Re: Voltage regulator
  • I would always switch the frame grounded side of the battery regardless of whether positive or negative ground. Switching the hot side still leaves a hot battery post if something were to short against it.

    Bob in KS    Posted 11-20-2018 at 17:06:56 [URL] [DELETE]        [Reply] [Email]  
  • Re: Voltage regulator
  • The generator is disconnected from the battery whenever the regulator cut out points are open

    TheOldHokie    Posted 11-20-2018 at 16:27:05 [URL] [DELETE]        [Reply] [Email]  
  • Re: Voltage regulator
  • You are actually flashing the generator and the answer is no. Residual magnetism is retained in the generator windings even when it is totally disconnected from the battery.

    TOH